Both sides previous revision Previous revision | Next revision Both sides next revision | ||
fabricademy2017:students:julie.taris:class9-e-textiles-wearables2 [2018/06/25 20:26] julie_taris |
fabricademy2017:students:julie.taris:class9-e-textiles-wearables2 [2018/06/25 20:39] julie_taris |
||
---|---|---|---|
Line 108: | Line 108: | ||
==7/let it dry for 4 hours== | ==7/let it dry for 4 hours== | ||
the drying depends of the cure time of the silicone. For ecoflex is 4 hours. | the drying depends of the cure time of the silicone. For ecoflex is 4 hours. | ||
+ | |||
+ | the excess silicone on the edges is removed to allow a better adhesion to the second part of the mold | ||
{{:fabricademy2017:students:julie.taris:julie-taris-ewearable2-1mmaplicator_8_.jpg?200x200|}} | {{:fabricademy2017:students:julie.taris:julie-taris-ewearable2-1mmaplicator_8_.jpg?200x200|}} | ||
Line 123: | Line 125: | ||
==9/pour a second silicone layer== | ==9/pour a second silicone layer== | ||
- | apply the second silicone layer using a mould of the same thickness as the first one | + | apply the second silicone layer using a mould of the same thickness as the first one. Repeat scrape from top to bottom with equal pressure. |
{{:fabricademy2017:students:julie.taris:julie-taris-hybrid-sensor-conductive-fabric-_27_.jpg?200x200|}} | {{:fabricademy2017:students:julie.taris:julie-taris-hybrid-sensor-conductive-fabric-_27_.jpg?200x200|}} | ||
Line 132: | Line 134: | ||
==10/hybrid sensor observations == | ==10/hybrid sensor observations == | ||
+ | |||
+ | The 4 sensor are on left part of the picture | ||
+ | |||
{{:fabricademy2017:students:julie.taris:hybridsensor-soft-robotic.jpg?200x200|}} | {{:fabricademy2017:students:julie.taris:hybridsensor-soft-robotic.jpg?200x200|}} | ||
+ | |||
+ | The sensor is released from its mold, with ecoflex we can see a really good flexibility and with pieces of leather a stretchy and strong sensor | ||
+ | |||
{{:fabricademy2017:students:julie.taris:julie-taris-hybrid-sensor-conductive-fabric-_29_.jpg?200x200|}} | {{:fabricademy2017:students:julie.taris:julie-taris-hybrid-sensor-conductive-fabric-_29_.jpg?200x200|}} | ||
{{:fabricademy2017:students:julie.taris:julie-taris-hybrid-sensor-conductive-fabric-_31_.jpg?200x200|}} | {{:fabricademy2017:students:julie.taris:julie-taris-hybrid-sensor-conductive-fabric-_31_.jpg?200x200|}} | ||
Line 139: | Line 147: | ||
{{:fabricademy2017:students:julie.taris:julie-taris-hybrid-sensor-conductive-fabric-_34_.jpg?200x200|}} | {{:fabricademy2017:students:julie.taris:julie-taris-hybrid-sensor-conductive-fabric-_34_.jpg?200x200|}} | ||
{{:fabricademy2017:students:julie.taris:julie-taris-hybrid-sensor-conductive-fabric-_38_.jpg?200x200|}} | {{:fabricademy2017:students:julie.taris:julie-taris-hybrid-sensor-conductive-fabric-_38_.jpg?200x200|}} | ||
+ | |||
+ | Compare to the left sensor, the right sensor : the fabric is not flat into the silicone and the layer is thicker so less flexible | ||
{{:fabricademy2017:students:julie.taris:julie-taris-hybrid-sensor-conductive-fabric-_39_.jpg?200x200|}} | {{:fabricademy2017:students:julie.taris:julie-taris-hybrid-sensor-conductive-fabric-_39_.jpg?200x200|}} | ||
{{:fabricademy2017:students:julie.taris:julie-taris-hybrid-sensor-conductive-fabric-_16_.jpg?200x200|}} | {{:fabricademy2017:students:julie.taris:julie-taris-hybrid-sensor-conductive-fabric-_16_.jpg?200x200|}} | ||
+ | On this one the fabric is wrinkled and the silicone layer too thick with a more important shore | ||
{{:fabricademy2017:students:julie.taris:julie-taris-ewearable2-1mmaplicator_20_.jpg?200x200|}} | {{:fabricademy2017:students:julie.taris:julie-taris-ewearable2-1mmaplicator_20_.jpg?200x200|}} | ||
{{:fabricademy2017:students:julie.taris:julie-taris-ewearable2-1mmaplicator_19_.jpg?200x200|}} | {{:fabricademy2017:students:julie.taris:julie-taris-ewearable2-1mmaplicator_19_.jpg?200x200|}} | ||
{{:fabricademy2017:students:julie.taris:julie-taris-ewearable2-1mmaplicator_21_.jpg?200x200|}} | {{:fabricademy2017:students:julie.taris:julie-taris-ewearable2-1mmaplicator_21_.jpg?200x200|}} | ||
{{:fabricademy2017:students:julie.taris:julie-taris-ewearable2-1mmaplicator_23_.jpg?200x200|}} | {{:fabricademy2017:students:julie.taris:julie-taris-ewearable2-1mmaplicator_23_.jpg?200x200|}} | ||
+ | |||
+ | a cutting test is performed to see if it is possible to cut once the sensor is finished : but cutting fabric with metallic fibers on this thickness and silicone damages the sensor too much. | ||
{{:fabricademy2017:students:julie.taris:julie-taris-ewearable2-1mmaplicator_24_.jpg?200x200|}} | {{:fabricademy2017:students:julie.taris:julie-taris-ewearable2-1mmaplicator_24_.jpg?200x200|}} |